MENU


632

The part was laser marked with a 20-watt q-switched ytterbium fiber laser and a 160 mm focal length lens. Process Parameters: Material: Aluminum Power: 12 Watts Method used: Surface Etch Frequency: 25 kHz Depth: Surface Speed: 10 inch/sec Laser Type: Q-Switched Fiber...

633

Medical Device Marking: The part was laser marked using a 20-watt q-switched ytterbium fiber laser with a 420 mm focal length lens, having a working distance of 493mm. Gloves were used to handle the parts before processing. The parts were surface annealed to create a...

634

Laser marking of the tool steel was accomplished with a 20 Watt fiber laser marking system. The tool steel was marked with dark marks, duplicating the example pieces sent to us. The part was marked with the logo and text. The cycle time for the laser marks using two...

635

Process Parameters: Large Parts – Dark Coating, Light Etch Material: Steel Power: 17 Watt Method used: Etching Frequency: 80 kHz Depth: Surface Speed: 3 inchsec Laser Type: Q-Switched Fiber Laser Focal Length Lens: 160mm (170mm WD) Cycle Time: 2.51 Seconds Process...