The parts were marked with a 20 watt q-switched ytterbium fiber laser and 160 mm focal length lens.

Process Parameters:

Material: Steel
Power: 16 Watts
Method used: Ablation
Frequency: 80 kHz
Depth: Surface
Speed: 10 inch/sec
Laser Type: Q-Switched Fiber Laser
Focal Length Lens: 160mm
Cycle Time: 5.09 seconds