The B Case, C Case & E Case parts were marked in the applications lab. The parts were marked as specified in the blueprints included with the capacitors. The whitish parts marked very well with the 20-watt q-switched ytterbium fiber laser. The dark brown parts did not produce as much contrast, but it did still mark. The smaller parts in the A Case were not marked since the applications lab was not currently stocked with a short enough focal length lens required to create such a small mark. The cycle times for the B case parts were 0.08 seconds, the C case parts had a cycle time of 0.115 seconds and the E case parts had a cycle time of 0.2 seconds.