The parts were marked using a 20 Watt Pulsed Fiber Laser using a 160 mm lens. The samples were ablated using 9 watts of power, with the frequency of 20 kHz, speed of 20″ per second, resulting in a cycle time of 0.25 second for the scale marking, 0.92 second for Mathews logo, and 0.81 seconds for the DMI logo.

Technology: Q-Switched Fiber Laser
Wattage: 20 Watt
Wavelength: 1060nm – 1070nm
Focal Length Lens: 160mm